Unrestrained torquing or forced insertion of the catheter or separator against resistance may result in damage to the device or vessel. Most recently, Penumbra launched LP System, including Ruby Coil LP and Packing Coil LP, which are low profile microcatheter compatible (.0165 - .021 ID). INDIGO Aspiration System Intended Use The healthcare firm said that the Indigo CAT RX Aspiration Catheters . (CAT3, CAT RX, CAT5, CAT6, CAT8, and CATD) and patented Separator technology, which maintains continuous aspiration and helps limit clogging of the catheters tip during the procedure. Relying on a different mechanism of action, power aspiration with CAT RX and Penumbra ENGINE was able to extract the thrombus intact; thus restoring flow through the graft. Caution: Prior to use, please refer to the Instructions for Use for complete product indications, contraindications, warnings, precautions, potential adverse events, and detailed instructions for use. Director, Structural Heart Jawairia Sahar K. Mirza, MBBS Contraindications Not for use in the coronaries or the neurovasculature. Excessive aspiration or failure to close the INDIGO Aspiration Tubing valve when aspiration is complete is not recommended. The Penumbra CAT RX catheter was used in a total of 34 patients, with 71% STEMI, 23% NSTEMI, 3% UA, and 3% new onset heart failure. Related Items. The patient underwent six shocks and was intubated while CAT RX was delivered through the freshly placed 3.5- X 38-mm DES to the PDA. Do not resterilize or reuse. Do not use in an oxygen rich environment. The Indigo System utilises the Penumbra ENGINE aspiration source capable of delivering nearly pure, continuous vacuum (-29 inHg or 98.2 kPa) to our catheters, enabling thrombus removal in vessels of various sizes. Two passes of CAT RX with the Penumbra ENGINE resulted in TIMI 3 flow restoration and retrieval of the distal emboli from the PDA (Figure 3). Initial experience with a mechanical aspiration catheter for thrombus removal during percutaneous intervention: a multicenter retrospective case series. K180412. Figure 1. Indigo System CAT RX tracking through the distal posterior tibial artery. Lightning Aspiration Tubing has dual pressure sensors for real-time blood flow monitoring. Use prior to the Use By date. The canister is intended for single use only. Control angiography immediately after thrombectomy demonstrated restored patency . As part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature. gtag('config', 'UA-18982160-1'); Penumbra Inc .cls-1{fill:#a6a699;}.cls-2{fill:#b5121b;}.cls-3{isolation:isolate;fill:url(#linear-gradient);}. Excessive aspiration or failure to close the INDIGO Aspiration Tubing when aspiration is complete is not recommended. The procedure can be performed quickly,1 which is important for symptomatic patients. Otherwise, this could result in degradation of the performance of this equipment. INDIGO SEPARATOR 4 is intended to be used with INDIGO CAT RX Aspiration Catheter to clear the distal end of the catheter lumen should it be blocked with thrombus. Do not use the INDIGO Aspiration System with a pump other than the Penumbra Aspiration Pump. The Indigo Aspiration System is comprised of several devices: The Indigo System may be used as a first-line approach or rescue therapy for arterial and venous thrombotic events. Waqas R. Qureshi, MD, MS The Indigo Aspiration System is contraindicated in: This allowed prompt treatment of patients with minimal intensive care unit days and early discharge from the hospital. Use prior to the Use By date. Figure 2. Possible complications include, but are not limited to, the following: allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arteriovenous fistula; death; device malfunction; distal embolization; emboli; false aneurysm formation; hematoma or hemorrhage at access site; inability to completely remove thrombus; Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower extremities, including below the knee. The product-specific content of this website is intended for use by healthcare professionals only. Potential Adverse Events Possible complications include, but are not limited to, the following: allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arteriovenous fistula; death; device malfunction; distal embolization; emboli; false aneurysm formation; hematoma or hemorrhage at access site; inability to completely remove thrombus; infection; hemorrhage; ischemia; kidney damage from contrast media; neurological deficits including stroke; vessel spasm, thrombosis, dissection, or perforation; intimal disruption; myocardial infarction; emergent surgery; fibrillation; hypotension; respiratory failure; peripheral thromboembolic events. Indigo Aspiration System (CAT RX and Separator 4)- Penumbra Engine Pump and Canister. When performing aspiration, ensure that the INDIGO Aspiration Tubing is open for only the minimum time needed to remove thrombus. An Interview With Binita Shah, MD, MS, FACC, FSCAI, By Mansi Oberoi, MD; M. Chadi Alraies, MD; and Poonam Velagapudi, MD, MS, Left Main Disease and Bifurcation Revascularization in Female Patients, By Tara L. Jones, MD, PharmD, and Valeria Paradies, MD, By Mirvat Alasnag, MD, FACP, FACC, FSCAI, FSCCT, Applying Team-Based Care Delivery to Interventional Cardiology: Learnings from the 2022 MedAxiom CV APP Survey, Understanding Sex Differences in Acute and Chronic Coronary Syndromes, By F. Aaysha Cader, MBBS, MD, MRCP(UK), MSc(Oxon); Rudaynah Amein Alali, MBBS, Internal Medicine Board, Interventional Cardiology Fellowship, RCPI; and Mirvat Alasnag, MD, FACP, FACC, FSCAI, FSCCT, SuperSaturated Oxygen Therapy: Cases and Cocktails Event Winning Presentations, With Charishma Nallapati, MD; Amer N. Kadri, MD; James Richard Spears, MD; Zaid Al-Jebaje, MD; Babar Basir, DO; and Khaldoon Alaswad, MD, FACC, FSCAI. The initial angiogram confirmed an occlusion with extensive thrombus burden of a dominant left circumflex artery and TIMI 0 flow (Figure 1). CAT8 Indigo Aspiration Catheter 8, TORQ tip, 85cm , 8Fr., Peripheral Thrombectomy Mechanical one eachCAT8 Indigo Aspiration Catheter 8, TORQ tip, 85cm , 8Fr., Peripheral Thrombectomy Mechanical one eachCAT8 Indigo Aspiration Catheter 8, TORQ tip, 85cm , 8Fr., Peripheral . 2015;372:1389-1398. Excessive aspiration or failure to close the INDIGO Aspiration Tubing when aspiration is complete is not recommended. Do not use kinked or damaged devices. Power aspiration with CAT RX has allowed us to successfully remove thrombus in patients presenting with acute coronary syndrome, establishing quick distal reperfusion and also visualization of the underlying stenosis. INDIGO Aspiration Tubing: As part of the INDIGO Aspiration System, the INDIGO Sterile Aspiration Tubing is indicated to connect the INDIGO Aspiration Catheters to the Penumbra Aspiration Pump. All Rights Reserved Privacy Policy, With S. Jay Mathews, MD, MS, FACC; Chris Metzger, MD; Waqas R. Qureshi, MD, MS; Jawairia Sahar K. Mirza, MBBS; Gus Theodos, MD, FACC, FSCAI; Brian Kolski, MD; Suhail Dohad, MD, FACC. Potential Adverse Events Tip directionality for circumferential aspiration, Live feedback during procedure with integrated clot catcher, Penumbra ENGINE is capable of delivering and maintaining nearly pure vacuum (-29 inHg or 98.2 kPa) with the disposablePenumbra ENGINE Canister. Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower . Do not re-infuse blood or fluid from the canister back into the patient. Do not use automated high-pressure contrast injection equipment with the INDIGO CAT RX Aspiration Catheter because it may damage the device. With automatic valve control, Lightning can help the physician focus on optimizing thrombus removal procedures. Do not use open or damaged packages. Possible complications include, but are not limited to, the following: Potential Adverse Events Possible complications include, but are not limited to, the following: allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arrhythmia/fibrillation; arteriovenous fistula; death; device malfunction; distal embolization; emergent surgery; false aneurysm formation; hematoma, hemorrhage, or blood loss at access site; hematoma, hemorrhage, or blood loss; hypotension; inability to completely remove thrombus or control blood flow; infection; ischemia; kidney damage from contrast media; myocardial infarction; neurological deficits including stroke; respiratory failure; thromboembolic events; vascular complications (including vessel spasm, thrombosis, intimal disruption, dissection, or perforation). Initial angiography revealed an occlusion of the distal RCA. Thrombus aspiration in patients with high thrombus burden in the TOTAL trial. Return all damaged devices and packaging to the manufacturer/distributor. The results may vary depending on a variety of patient specific attributes. Indigo Aspiration Catheters (CAT) are the foundation of Penumbra's Indigo System.The Indigo System CAT3, CAT5, CAT6, CAT8 and CATD are engineered to be robust, durable, and trackable for use in the peripheral anatomy. The Indigo System CAT8 catheter comes in three different tip designsstraight, 45, 90which allows a wide range of rotation. INDIGO Aspiration System with LIGHTNING Aspiration Tubing Indication for Use For more information on the personal data that is collected by this website, please refer to Penumbras Privacy Notice. Indigo Aspiration Catheters (CAT) are the foundation of Penumbra's Indigo System.The Indigo System CAT3, CAT5, CAT6, CAT8 and CATD are engineered to be robust, durable, and trackable for use in the peripheral anatomy. The patient was brought to the catheterization laboratory for angiography that showed stagnant flow through the saphenous vein graft (SVG; Figure 1). INDIGO Aspiration System Intended Use The INDIGO SEPARATOR is not intended for use as a guidewire. Jolly SS, Cairns JA, Yusuf S, et al. Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower extremities, including below the knee. Separator 8, 150 cm Length, 0.072 in. 22. The following case reports highlight CAT RX in a multitude of unique applications as a primary frontline device to treat patients with high thrombus burden. The built-in microprocessor features a proprietary thrombus removal algorithm that automatically controls a valve in the tubing to provide continuous or intermittent aspiration. 5, 19. Maintain a constant infusion of appropriate flush solution. This is potentially more effective than diminished syringe-based aspiration. Figure 2. Prior to the procedure, ticagrelor was administered and the patient was taken to the cardiac cath lab for angiography. Do not advance, retract or use any component of the INDIGO Aspiration System against resistance without careful assessment of the cause using fluoroscopy. Final angiographic result of SVG. Do not resterilize or reuse. The INDIGO Aspiration System should only be used by physicians who have received appropriate training in interventional techniques. Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower extremities, including below the knee. It is intended for use in the revascularization of patients with acute ischemic stroke secondary to intracranial large vessel occlusions. The CAT family of catheters is the foundation of Penumbra's Indigo System. As part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 (Penumbra, Inc.) are indicated for the removal of fresh soft emboli and thrombi from vessels in the coronary and peripheral vasculature. Copyright 2022 Penumbra, Inc. All rights reserved. CAT12 features a large 0.131 lumen and angled tip for additional circumferential sweep. 1.10 Summary of Non-Clinical Data As required under Section 12, Part (a)(i)(3A) of the Safe Medical Devices Act of 1990, a We decided to start with mechanical aspiration using CAT RX and Penumbra ENGINE to extract the thrombus. The Indigo Aspiration System is intended for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and certain central circulatory system conditions such as pulmonary emboli using continuous aspiration. The CAT family of catheters is the foundation of Penumbra's Indigo System. Common emitters (such as RFID emitters, security systems, diathermy equipment, and portable transmitters) should not be used in close proximity to the PENUMBRA ENGINE as they can interfere with and result in degradation of the performance of the equipment. Return all damaged devices and packaging to the manufacturer/distributor. BJC Cardiology If the cause cannot be determined, withdraw the device or system as a unit. The Penumbra Aspiration Pump is indicated as a vacuum source for Penumbra Aspiration Systems. Vedantham S, Goldhaber SZ, Julian JA, et al. Penumbra's high-performance aspiration catheters. There were no cases of 30-day cardiovascular death or post procedural stroke. System Chair, Clinical Research Angiography was performed and confirmed complete thrombus removal and flow restoration through the SVG. Tip directionality for circumferential aspiration, Live feedback during procedure with integrated clot catcher, Penumbra ENGINE is capable of delivering and maintaining nearly pure vacuum (-29 inHg or 98.2 kPa) with the disposablePenumbra ENGINE Canister. The patients symptoms normalized, the electrocardiogram stabilized, and the acute MI was immediately resolved. INDIGO Aspiration Catheters and Separators: As part of the INDIGO Aspiration System, the INDIGO Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism. Lightning Aspiration Tubing has dual pressure sensors for real-time blood flow monitoring. The Penumbra IndigoSystem Separatoris intended for use with our Indigo Systems CATfamily of catheters to enable the removal of a wide range of thrombus. The procedure was completed with the same catheter. At our institutions, we are using CAT RX for patients who present with fresh soft thrombi or emboli. UPC: Current Stock: This item is out of stock. With automatic valve control, Lightning can help the physician focus on optimising thrombus removal procedures. Return all damaged devices and packaging to the manufacturer/distributor. Copyright 2023 Penumbra, Inc. All rights reserved. Penumbra Aspiration Pump: The Penumbra Aspiration Pump is indicated as a vacuum source for Penumbra Aspiration Systems. Indigo Aspiration Catheters (CAT) are the foundation of Penumbra's Indigo System. The CAT family of catheters is the foundation of Penumbra's Indigo system. Penumbra introduced the Indigo System CAT RX in 2017 for the removal of fresh, soft emboli and thrombi from the . We started with laser atherectomy followed by percutaneous transluminal angioplasty of the tibial peroneal trunk, peroneal artery, and posterior tibial artery. It will reduce service life of the Penumbra ENGINE. N Engl J Med. These types of burns heal withing 5 or 6 days without permanent scarring. The Penumbra IndigoSystem Separatoris intended for use with our Indigo Systems CATfamily of catheters to enable the removal of a wide range of thrombus. Copyright 2023 Penumbra, Inc. All rights reserved. TIMI 3 flow was achieved in 88% of cases. Manual aspiration using a Pronto V3 (Teleflex) catheter restored some flow, however, distal embolization to the posterior descending artery (PDA) immediately caused right ventricular cardiac arrest (Figure 2). UMassMemorial University Campus The initial angiogram confirmed a distal occlusion of the RCA with TIMI 0 flow and extensive clot burden (Figure 1). Do not position the Penumbra ENGINE so that it is difficult to remove the power cord. Penumbras Indigo Aspiration System can be used to remove emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism and/or certain central circulatory system conditions such as pulmonary emboli. 0, 24. As part of the INDIGO Aspiration System, the INDIGO Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism. gus.theodos@bjc.org; @gtheodosmd The Indigo System CAT RX with Penumbra ENGINE is an invaluable tool that is easy to set up and can provide rapid thrombectomy and immediate reperfusion. Lightning 12 and Lightning 8 expand the already broad offering of CAT8, CATD, CAT6, CAT5, and CAT3 and are paired with Penumbra ENGINE, the company's proprietary continuous, mechanical vacuum . Indigo System CAT RX has been designed to address the limitations of traditional treatment options with manual aspiration. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally. Penumbra System BENCHMARK Delivery Catheter - MP - 6Fr x .071" x 105cm - Non-Expired: 6Fr x .071" x 105cm $550.00. Do not use Indigo Separator 4 to macerate or retrieve thrombus distal to the catheter tip. Figure 1. INDIGO Aspiration Catheters and Separators: As part of the INDIGO Aspiration System, the INDIGO Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism. Smidt Heart institute kolskiwellness@gmail.com Return all damaged devices and packaging to the manufacturer/ distributor. infection; hemorrhage; ischemia; kidney damage from contrast media; neurological deficits including stroke; vessel spasm, thrombosis, dissection, or perforation; intimal disruption; myocardial infarction; emergent surgery; fibrillation; hypotension; respiratory failure; peripheral thromboembolic events. Do not use automated high-pressure contrast injection equipment with the INDIGO Aspiration Catheter because it may damage the device.